K.D.
StadiumŪ Locker Overview The K.D.
(Knocked Down, or Unassembled) Penco
StadiumŪ lockers have an open
front and perforated sides providing a fully ventilated space
for storage of athletic gear or other items. The base model
is an open shell with a full width shelf. A security box fastened
to the shelf and a foot locker with a hinged, reinforced seat
at the base are popular options. They are available in 24" or
33" widths and 18", 21" or 24" depths. K.D. Stadium lockers
are 72" high. STADIUM LOCKER (KD) SPECIFICATIONS MATERIALS SHEET STEEL: All parts made from prime
grade mild cold rolled sheet steel free from surface imperfection,
and capable of taking a high grade enamel finish. FINISHING: Chemically
pretreat metal with a six stage cleaning phosphatizing and
metal preparation process. Finish coat shall be electrostatically
applied powder coat enamel baked on at 350 to 400 degrees.
Select colors from manufacturer's minimum standard 21 colors.
All lockers shall be painted inside and outside with the same
color.
EQUIPMENT: Coat hooks and coat rods
are zinc plated. Truss fin head bolts and hex nuts are zinc coated. FABRICATION GENERAL CONSTRUCTION: Lockers
shall be fabricated square, rigid and without warp. LOCKER FRAME: Locker frame member to
be not less than 16 gauge formed to a channel shape. Intermembering
parts to be mortised and tenoned and electrically welded together
in a rigid assembly capable of resisting strains. BODY: Bolt
spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made
of cold rolled steel specially formed for added strength and rigidity
and to ensure tight joints at fastening points. Tops & bottoms
shall be 16 gauge with three sides formed 90 degrees and the front
offset formed to be flush with the horizontal frame member. Bottoms
have two reinforcement channels for added strength. Shelves shall
be 16 gauge with four sides formed to 90 degrees, the front edge
shall have a second bend. Side panels shall be 16 gauge while the
back panel shall be 18 gauge. SHELF: 16 gauge with four sides formed
to 90 degrees, the front edge shall have a second bend. VENTILATION: For maximum ventilation
locker has an open front. Side panels are to be perforated with
diamond-shaped openings unless otherwise specified. NUMBER PLATES: Each
locker to be supplied with a polished aluminum number plate,
2-1/4" wide x 1" high, with
black numerals not less than 3/8" high. Number plates to be attached
to the center of shelf with two aluminum rivets. INTERIOR EQUIPMENT: Each locker is provided
with a set of rod holders, one coat rod and two single prong hooks
(to be fastened to the back panel). OPTIONS SECURITY BOX: 14 gauge lockable
door with a 16 gauge side panel. The door is attached to a welded
frame with a continuous hinge. The hinge is mounted to door with
aluminum rivets. The door is locked through a single point latch
with a padlock or built in lock. A lock hole cover plate shall
be provided for use with padlocks. Security box door frame to be
not less than 16 gauge formed to a channel shape. Vertical members
to have an additional flange to provide a continuous door strike.
Intermembering parts to be mortised and tenoned and electrically
welded together in a rigid assembly capable of resisting strains. FOOT LOCKER: Front foot locker panel
includes single point latch with padlock strike plate and mini
louvers. Lid of foot locker has a continuous hinge and also serves
as a seat. Opening and closing of the lid is quieted by rubber
bumpers mounted to the contact points. The seat lid is strengthened
with two reinforcement channels welded to bottom. Two side seat
supports are bolted to side panels and inserted in a support tab
on the front locker panel for added strength. SOLID SIDE PANELS: Side panels shall
be void of ventilation holes. BODY: Locker shall be assembled using
rivets. EXECUTION INSTALLATION: Install metal
lockers at location shown in accordance with manufacturers instructions
for plumb, level, and flush installation. ANCHOR LOCKERS to
the floor and wall 48" on center or less as recommended by
the manufacturer. ADJUST & CLEAN: Adjust doors and latches
to operate without binding. Verify that latches are operating satisfactorily. TOUCH UP: Marred finishes with factory
supplied paint. ACCEPTABLE MANUFACTURERS 1. Penco Products,
Inc., Oaks, PA - Stadium Locker PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS
CONSISTENT WITH ITS POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.
11/11/2004
|