Guardian Plus Locker Overview
This locker is the same design as the Guardian
Standard, with the exception that the door is manufactured from heavier
14 gauge steel. This is ideally suited for school corridors where
heavier than usual abuse, is anticipated.
GUARDIAN PLUS LOCKER SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime
grade mild cold rolled sheet steel free from surface imperfection,
and capable of taking a high grade enamel finish.
HINGES: .074" thick, 2" high,
double spun, full loop, tight pin, five-knuckle hinges, projection
welded to door frame and securely fastened to the door with 2 steel
rivets. Doors over 42" high shall have three hinges, all other
doors shall have two hinges.
FINISHING: Chemically
pretreat metal with a six stage cleaning phosphatizing and metal
preparation process. Finish
coat shall be
electrostatically applied powder coat enamel baked on at 350 to 400
degrees. Select colors from manufacturer's minimum standard 21 colors.
All
lockers
shall be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are
zinc plated. Truss fin head bolts and hex nuts are zinc plated.
FABRICATION GENERAL
CONSTRUCTION: Built on the unit principle
- each locker shall have an individual door and frame, individual
top, bottom, back and shelves with common intermediate uprights separating
compartments. Lockers shall be fabricated square, rigid and without
warp. Doors shall be flat and free of distortion.
DOOR FRAME: All door frame members to be
not less than 16 gauge formed to a channel shape. Vertical members
to have an additional flange to provide a continuous door strike.
Intermembering parts to be mortised and tenoned and electrically
welded together in a rigid assembly capable of resisting strains.
Cross frame members of 16 gauge channel shapes
including intermediate cross frame on double and triple tier lockers
shall be securely welded to vertical framing members to ensure rigidity.
BODY: Bolt
spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made
of cold rolled steel specially formed for added strength and rigidity
and to ensure tight joints at fastening points. Tops & bottoms
shall be 24 gauge with three sides formed 90 degrees and the front
offset formed to be flush with the horizontal frame member. Shelves
shall be 24 gauge with four sides formed to 90 degree, the front
edge shall have a second bend. Backs & sides shall be 24 gauge.
DOORS: Doors
shall be 14 gauge steel. Doors 24" wide x 60" or 72" high shall have one door per
opening and four hinges per door. Formations shall consist of a full
channel shape on the lock side of adequate depth to fully conceal
the lock bar, channel formation on the hinge side, and right angle
formations across the top and bottom. Doors over 15" wide x
60" or 72" high shall have a 3" wide 20 gauge full
height reinforcing pan welded to the inside face of the door on 6" centers.
DOOR
HANDLE & LATCHING: Handles shall
be recessed in the door and be finger lift control. The 20 gauge
drawn pocket shall be brushed stainless steel securely fastened to
the door with two tabs plus a positive tamper resistant decorative
fastener. The pocket shall be of sufficient depth to prevent a combination
padlock, built-in combination lock or key lock from protruding beyond
the face of the door. A lock hole cover plate shall be provided for
use with padlocks.
The
lifting piece shall be 14 gauge formed steel, attached to the latching
channel with one concealed retaining lug
and one rivet assuring a positive two point connection. Handle finger
lift shall have a padlock eye for use with a 9/32" diameter
padlock shackle. It shall have a sound deadening molded comfortable
finger lift attached with a rivet. The bottom of the pocket shall
have holes for attaching the number plate with two aluminum rivets,
and shall be angled to facilitate visibility of the number plate.
Doors
to have latch clip engaging the door frame at three points on 60" or 72" high and two points on 20" through
36" high doors. Locking device to be positive, automatic type,
whereby locker door may be locked when open, then closed without
unlocking. One rubber silencer shall be firmly secured in the frame
at each heavy gauge latch hook. Latch clips shall be glass filled
nylon for long life and low friction and shall hold doors shut by
engaging the latch hooks. The latch channel assembly shall be quieted
by the use of unique nylon glides to reduce noise.
VENTILATION: Shall
be facilitated by air flow slots located in the top & bottom
flange of the door. The door front shall be flush with no exposed
louvers.
NUMBER PLATES: Each
locker to be supplied with a polished aluminum number plate, 2-1/4" wide x 1" high,
with black etched numerals not less than 3/8" high. Number plates
shall be located on the lower face of the recess pocket and shall
be attached with two aluminum rivets.
INTERIOR EQUIPMENT: Single
tier lockers 60" or higher shall have a hat shelf located approximately 9" below
the top of locker; if less than 18" deep, locker shall have
three single-prong hooks and one double-prong ceiling hook. Single
tier lockers 18" or more in depth shall have a coat rod instead
of a ceiling hook. 30" & 36" high lockers shall have
three single-prong wall hooks and one double-prong ceiling hook.
Hooks to be steel, ball tip zinc plated, attached with two bolts
per hook. 20" & 24" high lockers to have three wall
hooks for 12" wide and four wall hooks for 15" and wider.
LOCKER ACCESSORIES: Lockers shall be furnished
with the accessories selected from the Accessory Specifications.
OPTIONS
BODY: Lockers shall be assembled using
rivets.
A. D. A. COMPLIANT LOCKERS:
Handicap lockers shall have recessed handles and shall be single
tier or the lower
opening of a double tier locker. Locker bottom shall be a minimum
of 9" off the floor, or an extra shelf placed 9" off the
floor. Single tier lockers shall have a shelf 48" off the floor.
Doors assigned for handicapped use shall have an appropriate symbol
sign.
EXECUTION
INSTALLATION: Install metal lockers at
location shown in accordance with manufacturer's instructions for
plumb, level, and flush installation.
ANCHOR LOCKERS to
the floor and wall 48" on
center or less as recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using
concealed fasteners. Provide flush hairline joints against adjacent
surfaces.
INSTALL BENCHES by fastening bench tops
to pedestals and securely anchoring to the floor using appropriate
anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches
to operate without binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied
paint.
ACCEPTABLE MANUFACTURERS
1. Penco Products, Inc., Oaks, PA - Guardian Plus
Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS
CONSISTENT WITH ITS POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.