| Guardian
Locker Overview
Guardian lockers feature stainless steel
recessed handles and louverless doors. Special nylon glides fastened
to the latch channel assembly help to minimize noise. Air flow
slots are located in the top and bottom flanges of the door.
Doors accept built-in locks or padlocks.
Standard Guardian lockers are available in two optional types:
1. Guardian Medallion locker doors have a sound-deadening
pan welded to the inside of the door.
2. Guardian Plus locker doors are made from 14 gauge steel, for use in areas
where heavier than usual abuse is expected.
GUARDIAN LOCKER SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime
grade mild cold rolled sheet steel free from surface imperfection,
and capable of taking a high grade enamel finish.
HINGES: .074" thick, 2" high, double spun,
full loop, tight pin, five-knuckle hinges, projection welded to door
frame and securely fastened to the door with 2 steel rivets. Doors
over 42" high shall have three hinges, all other doors shall have
two hinges.
FINISHING: Chemically
pretreat metal with a six stage cleaning phosphatizing and metal
preparation process. Finish
coat shall be
electrostatically applied powder coat enamel baked on at 350 to 400
degrees. Select colors from manufacturer's minimum standard 21 colors.
All
lockers
shall be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are
zinc plated. Truss fin head bolts and hex nuts are zinc plated.
FABRICATION GENERAL CONSTRUCTION: Built
on the unit principle - each locker shall have an individual door
and frame, individual top, bottom, back and shelves with common intermediate
uprights separating compartments. Lockers shall be fabricated square,
rigid and without warp. Doors shall be flat and free of distortion.
DOOR FRAME: All door frame members to be
not less than 16 gauge formed to a channel shape. Vertical members
to have an additional flange to provide a continuous door strike.
Intermembering parts to be mortised and tenoned and electrically
welded together in a rigid assembly capable of resisting strains.
Cross frame members of 16 gauge channel shapes including intermediate
cross frame on double and triple tier lockers shall be securely welded
to vertical framing members to ensure rigidity.
BODY: Bolt
spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made of
cold rolled steel specially formed for added strength and rigidity
and to ensure tight joints at fastening points. Tops & bottoms shall
be 24 gauge with three sides formed 90 degrees and the front offset
formed to be flush with the horizontal frame member. Shelves shall
be 24 gauge with four sides formed to 90 degree, the front edge shall
have a second bend. Backs & sides shall be 24 gauge.
DOORS: Doors
20" or higher shall be formed
from one piece 16 gauge cold rolled sheet steel. Formations shall
consist of a full channel shape on the lock side of adequate depth
to fully conceal the lock bar, channel formation on the hinge side,
and right angle formations across the top and bottom. Doors over
15" wide x 60" or 72" high shall have a 3" wide 20 gauge full height
reinforcing pan welded to the inside face of the door on 6" centers.
Doors less than 12" wide shall be 18 gauge.
DOOR
HANDLE & LATCHING: Handles shall be
recessed in the door and be finger lift control. The 20 gauge drawn
pocket shall be brushed stainless steel securely fastened to the
door with two tabs plus a positive tamper resistant decorative fastener.
The pocket shall be of sufficient depth to prevent a combination
padlock, built-in combination lock or key lock from protruding beyond
the face of the door. A lock hole cover plate shall be provided for
use with padlocks. The lifting piece shall be 14 gauge formed steel,
attached to the latching channel with one concealed retaining lug
and one rivet assuring a positive two point connection. Handle finger
lift shall have a padlock eye for use with a 9/32" diameter padlock
shackle. It shall have a sound deadening molded comfortable finger
lift attached. Doors to have latch clip engaging the door frame at
three points on 60"& 72" high and two points on 20" through 36" high
doors. Locking device to be positive, automatic type, whereby locker
door may be locked when open, then closed without unlocking. One
rubber silencer shall be firmly secured in the frame at each heavy
gauge latch hook. Latch clips shall be glass filled nylon for long
life and low friction and shall hold doors shut by engaging the latch
hooks. The latch channel assembly shall be quieted by the use of
unique nylon glides to reduce noise.
VENTILATION: Shall
be facilitated by air flow slots located in the top & bottom flange
of the door. The door front shall be flush with no exposed louvers.
NUMBER PLATES: Each
locker door to be supplied with a polished aluminum number plate,
2-1/4" wide x 1" high, with
black numerals not less than 3/8" high. Number plates shall be attached
to the face of the door with two aluminum rivets.
INTERIOR EQUIPMENT: Single
tier lockers 60" or higher shall have a hat shelf located approximately 9" below
the top of locker; if less than 18" deep, locker shall have three
single-prong hooks and one double-prong ceiling hook. Single tier
lockers 18" or more in depth shall have a coat rod instead of a ceiling
hook. 30" & 36" high lockers shall have three single-prong wall hooks
and one double-prong ceiling hook. Hooks to be steel, ball tip zinc
plated, attached with two bolts per hook. 20" & 24" high lockers
to have three wall hooks for 12" wide and four wall hooks for 15" and
wider.
LOCKER ACCESSORIES: Lockers shall be furnished
with the accessories selected from the Accessory Specifications.
OPTIONS: BODY: Lockers shall be assembled
using rivets.
MEDALLION OPTION: Sound-dampening panels
are spot welded flush to the inside of the door and contain sound
absorbing material to reduce noise levels when doors are slammed.
They are 22 gauge and have a full perimeter flange. Louvers are not
used when sound-dampening panels are provided.
GUARDIAN PLUS OPTION: Doors
shall be 14 gauge steel. Formations shall consist of a full channel
shape on
the lock side of adequate depth to fully conceal the lock bar, channel
formation on the hinge side, and right angle formations across the
top and bottom. Doors over 15" wide x 60" or 72" high shall have
a 3" wide 20 gauge full height reinforcing pan welded to the inside
face of the door on 6" centers. Doors 24" wide x 60" or 72" high
shall have one door per opening and four hinges per door.
A. D. A. COMPLIANT LOCKERS: Handicap
lockers shall have recessed handles and shall be single tier or
the lower
opening of a double tier locker. Locker bottom shall be a minimum
of 9" off the floor, or an extra shelf placed 9" off the floor. Single
tier lockers shall have a shelf 48" off the floor. Doors assigned
for handicapped use shall have an appropriate symbol sign.
DOOR VENTILATION: Mini
louvers shall be 5/8" wide x 1/4" high and be placed in doors in
manufacturer's standard pattern. Doors with mini louvers shall
not have standard louvers.
EXECUTION INSTALLATION: Install metal lockers
at location shown in accordance with manufacturer's instructions
for plumb, level, and flush installation.
ANCHOR LOCKERS to
the floor and wall 48" on
center or less as recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using
concealed fasteners. Provide flush hairline joints against adjacent
surfaces.
INSTALL BENCHES by fastening bench tops
to pedestals and securely anchoring to the floor using appropriate
anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches
to operate without binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied
paint.
ACCEPTABLE MANUFACTURERS
1. Penco Products, Inc., Oaks, PA - Guardian Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS
CONSISTENT WITH ITS POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.
11/11/04 |