Locker Overview
Available in 1, 2 and 3 tier models.
Same as the Guardian Lockers except that these lockers have stiffening pans and a full length continuous hinge.
For ease of maintenance, there are no moving latch parts. Stainless
steel recessed pocket has integral finger grip door pull. Accepts
built-in locks or padlocks.
GUARDIAN DEFIANT II SINGLE POINT LATCH (SPL)
LOCKER SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime
grade mild cold rolled sheet steel free from surface imperfection,
and capable of taking a high grade enamel finish.
HINGES: 16 gauge continuous hinges (full length of the door) are welded to the door and riveted to the frame.
FINISHING: Chemically
pretreat metal with a six stage cleaning phosphatizing and metal
preparation process. Finish
coat shall be
electrostatically applied powder coat enamel
properly cured to paint manufacturer specifications to achieve optimum performance. Select colors from manufacturer's minimum standard 21 colors.
All
lockers
shall be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are
zinc plated. Truss fin head bolts and hex nuts are zinc plated.
FABRICATION GENERAL
CONSTRUCTION: Built on the unit principle
- each locker shall have an individual door and frame, individual
top, bottom, back and shelves with common intermediate uprights separating
compartments. Lockers shall be fabricated square, rigid and without
warp. Doors shall be flat and free of distortion.
DOOR FRAME: All door frame members to be
not less than 16 gauge formed to a channel shape. Vertical members
to have an additional flange to provide a continuous door strike.
Intermembering parts to be mortised and tenoned and electrically
welded together in a rigid assembly capable of resisting strains.
Cross frame members of 16 gauge channel shapes including intermediate cross
frame on double and triple tier lockers shall be securely welded to vertical
framing members to ensure rigidity.
BODY: Bolt
spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made
of cold rolled steel specially formed for added strength and rigidity
and to ensure tight joints at fastening points. Tops & bottoms
shall be 24 gauge with three sides formed 90 degrees and the front
offset formed to be flush with the horizontal frame member. Shelves
shall be 24 gauge with four sides formed to 90 degrees, the front
edge shall have a second bend. Backs & sides shall be 24 gauge.
DOORS: All doors shall be formed from 14 gauge steel. Formations shall be channel shape on the hinge and latch sides, and right angle formations across the top and bottom. Top and bottom flanges shall have one 90 degree bend. The latch side formation shall include a slot to fully engage an additional anti-pry lug integral with the padlock hasp limiting motion in any direction. On doors measuring 12” through 18” wide, additional reinforcement shall be in the form of a vertical 18 gauge pan measuring 3-1/2” wide, MIG-welded to the top and bottom flanges and hinge side channel, with an additional ½“ flange spot welded a maximum of 8" on center to the door skin to maximize door rigidity. Doors measuring more than 18” wide shall be reinforced using a 20 gauge horizontal box pan MIG-welded a maximum of 8" on center to the hinge and latch side channels, and spot welded to the door skin a maximum of 8" on center along the upper and lower pan edge for optimum strength, quiet operation and stiffness. Door shall be manufactured to allow ventilation and stiffness.
DOOR
HANDLE & LATCHING 1, 2 & 3 TIER: Handles shall be recessed in the door. The formed pocket shall be brushed stainless steel securely fastened to the door with two lugs plus a positive tamper resistant fastener. The pocket shall be of sufficient depth to prevent a combination padlock, built-in combination lock or key lock from protruding beyond the face of the door. An anti-pry lock alignment bracket shall be supplied for use with built-in combination locks to facilitate installation, adjustment and to increase resistance to prying by mechanically engaging the hasp assembly. A lock hole cover plate shall be provided for use with padlocks. All pockets shall be 22 gauge drawn stainless steel for superior strength. Door pull shall be formed in the pocket. Pocket and pull shall be integral.
Doors shall have a catch to retain unlocked doors in the closed position. Locking shall be accomplished by an 11 gauge lug welded to the locker frame. The lug shall include a surface for the bolt of a built-in combination or key lock to engage. A padlock staple shall protrude through the 22 gauge pocket. The hasp assembly shall include an additional lug that mechanically engages a slot on the latch side door formation preventing the spreading of the door from the frame channel. A separate bracket shall be field installed to brace the lock hasp assembly against the locker side to prevent twisting of the frame. Rubber door silencers shall be firmly attached to the locker frame.
VENTILATION: Shall
be facilitated by air flow slots located in the top & bottom
flange of the door. The door front shall be flush with no exposed
louvers.
NUMBER PLATES: Each
locker door to be supplied with a polished aluminum number plate,
2-1/4" wide x 1" high,
with black numerals not less than 3/8" high. Number plates shall
be attached to the face of the door with two aluminum rivets.
INTERIOR EQUIPMENT: Single
tier lockers 48-1/2" or higher shall have a hat shelf located approximately 9" below
the top of locker; if less than 18" deep, locker shall have
three single-prong hooks and one double-prong ceiling hook. Single
tier lockers 18" or more in depth shall have a coat rod instead
of a ceiling hook. 30" & 36" high lockers shall have
three single-prong wall hooks and one double-prong ceiling hook.
Hooks to be steel, ball tip zinc plated, attached with two bolts
per hook. 20" & 24" high lockers to have three wall
hooks for 12" wide and four wall hooks for 15" and wider.
LOCKER ACCESSORIES: Lockers shall be furnished
with the accessories selected from the Accessory Specifications.
OPTIONS
BODY: Lockers shall be assembled using
rivets.
DOOR VENTILATION: Mini
louvers shall be 5/8" wide x 1/4" high and be placed
in doors in manufacturer's standard pattern.
DOOR REINFORCEMENT: A horizontal pan on 9” through 18” wide doors when specified. Horizontal pans shall measure 8” vertically on 20” or 24” tall doors; 14” on 30” or 36” tall doors, 17” on 48” tall doors; 26” on 60” tall doors and 32” on 72” tall doors. Top and bottom flanges on all doors shall have one 90 degree bend. All doors shall be manufactured to allow maximum ventilation and stiffness.
EXECUTION
INSTALLATION: Install metal lockers at
location shown in accordance with manufacturer's instructions for
plumb, level, and flush installation.
ANCHOR LOCKERS to
the floor and wall 48" on
center or less as recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using
concealed fasteners. Provide flush hairline joints against adjacent
surfaces.
INSTALL BENCHES by fastening bench tops
to pedestals and securely anchoring to the floor using appropriate
anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches
to operate without binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied
paint.
ACCEPTABLE MANUFACTURERS
1. Penco Products, Inc., Oaks, PA - Guardian Defiant II (SPL) Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS CONSISTENT WITH ITS POLICY
OF CONTINUOUS PRODUCT IMPROVEMENT.