Invincible
II Defiant II Single Point Latch (SPL)
Locker Overview
Available in 1, 2 and 3 tier models.
Same as the Invincible II Lockers except that these lockers have stiffening pans and a full length continuous hinge.
For ease of maintenance, there are no moving latch parts. Stainless
steel recessed pocket has integral finger grip door pull. Accepts
built-in locks or padlocks.
INVINCIBLE II HEAVY DUTY VENTILATED LOCKER
WITH DEFIANT II SINGLE POINT LATCH (SPL) SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime
grade mild cold rolled sheet steel free from surface imperfection,
and capable of taking a high grade enamel finish.
HINGES: 16 gauge continuous type hinge riveted to the frame and welded to the door for the full height of the door.
FINISHING: Chemically
pretreat metal with a six stage cleaning phosphatizing and metal
preparation process. Finish coat shall be electrostatically applied
powder coat enamel
properly cured to paint manufacturer specifications to achieve optimum performance. Select colors
from manufacturer's minimum standard 21 colors. All lockers shall
be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are
zinc plated. Truss fin head bolts and hex nuts are zinc plated.
FABRICATION
GENERAL CONSTRUCTION: Built on the unit
principle - each locker shall have an individual door and frame,
individual top, bottom, back and shelves with common intermediate
uprights separating compartments. Lockers shall be fabricated square,
rigid and without warp. Doors shall be flat and free of distortion.
DOOR FRAME: All door frame members to be
not less than 16 gauge formed to a channel shape. Vertical members
to have an additional flange to provide a continuous door strike.
Intermembering parts to be mortised and tenoned and electrically
welded together in a rigid assembly capable of resisting strains.
Cross frame members of 16 gauge channel shapes including intermediate
cross frame on double and triple tier lockers shall be securely welded
to vertical framing members to ensure rigidity.
BODY: Bolt
spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made of
cold rolled steel specially formed for added strength and rigidity
and to ensure tight joints at fastening points. Tops & bottoms shall
have three sides formed 90 degrees and the front offset formed to
be flush with the horizontal frame member. Shelves shall have sides
formed to 90 degrees, the front edge shall have a second bend. Backs
shall be 18 gauge; all other body parts shall be 16 gauge.
DOORS: All doors shall be formed from 14 gauge steel. Formations shall be channel shape on the hinge and latch sides, and right angle formations across the top and bottom. Top and bottom flanges shall have one 90 degree bend. The latch side formation shall include a slot to fully engage an additional anti-pry lug integral with the padlock hasp limiting motion in any direction. On doors measuring 12” through 18” wide, additional reinforcement shall be in the form of a vertical 18 gauge pan measuring 3-1/2” wide MIG-welded to the top and bottom flanges and hinge side channel, with an additional ½“ flange spot welded a maximum of 8"on center to the door skin to maximize door rigidity. Doors measuring more than 18” wide shall be reinforced using a 20 gauge horizontal box pan MIG-welded a maximum of 8" on center to the hinge and latch side channels, and spot welded a maximum of 8” on center to the door skin along the upper and lower pan edge for optimum strength, quiet operation and stiffness. Door shall be manufactured to allow ventilation and stiffness.
DOOR
HANDLE & LATCHING 1, 2 & 3 TIER: Handles shall be recessed in the door. The formed pocket shall be brushed stainless steel securely fastened to the door with two lugs plus a positive tamper resistant fastener. The pocket shall be of sufficient depth to prevent a combination padlock, built-in combination lock or key lock from protruding beyond the face of the door. An anti-pry lock alignment bracket shall be supplied for use with built-in combination locks to facilitate installation, adjustment and to increase resistance to prying by mechanically engaging the hasp assembly. A lock hole cover plate shall be provided for use with padlocks. All pockets shall be 22 gauge drawn stainless steel for superior strength. Door pull shall be formed in the pocket. Pocket and pull shall be integral.
Doors shall have a catch to retain unlocked doors in the closed position. Locking shall be accomplished by an 11 gauge lug welded to the locker frame. The lug shall include a surface for the bolt of a built-in combination or key lock to engage. A padlock staple shall protrude through the 22 gauge pocket. The hasp assembly shall include an additional lug that mechanically engages a slot on the latch side door formation preventing the spreading of the door from the frame channel. A separate bracket shall be field installed to brace the lock hasp assembly against the locker side to prevent twisting of the frame. Rubber door silencers shall be firmly attached to the locker frame.
VENTILATION: All
locker sides and doors 20" or higher shall be perforated with diamond-shaped openings 3/4" wide
x 1-1/2" high in a quantity and pattern to insure maximum ventilation
and maintain structural strength. All other doors shall have small
diamond-shaped perforations 7/16" wide x 15/16" high.
NUMBER PLATES: Each
locker door to be supplied with a polished aluminum number plate,
2-1/4" wide x 1" high, with
black numerals not less than 3/8" high. Number plates shall be attached
to the face of the door with two aluminum rivets.
INTERIOR EQUIPMENT: Locker
openings 48-1/2" or
higher shall have a hat shelf located approximately 9" below the
top of locker. Locker openings 30" or higher, 12" or 15" wide and
less than 18" deep shall have three single-prong hooks and one double-prong
ceiling hook. Lockers 18" or more in depth shall have a coat rod
instead of a ceiling hook. 20" & 24" lockers shall have three wall
hooks only. Hooks to be steel, ball tip zinc plated, attached with
two bolts per hook.
LOCKER ACCESSORIES: Lockers shall be furnished
with the accessories selected from the Accessory Specifications.
OPTIONS
BODY: Lockers shall be assembled using
rivets.
DOOR VENTILATION: Delete
diamond perforations in the doors and substitute with standard
louvers, or mini louvers
may be substituted and shall be 5/8" wide x 1/4" high. Louvers shall
be placed in doors in manufacturer's standard pattern.
DOOR REINFORCEMENT: A horizontal pan on 9” through 18” wide doors when specified. Horizontal pans shall measure 8” vertically on 20” or 24” tall doors; 14” on 30” or 36” tall doors, 17” on 48” tall doors; 26” on 60” tall doors and 32” on 72” tall doors. Top and bottom flanges on all doors shall have one 90 degree bend. All doors shall be manufactured to allow maximum ventilation and stiffness.
EXECUTION:
INSTALLATION: Install metal lockers at
location shown in accordance with manufacturers instructions for
plumb, level, and flush installation.
ANCHOR LOCKERS to
the floor and wall 48" on
center or less as recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using
concealed fasteners. Provide flush hairline joints against adjacent
surfaces.
INSTALL BENCHES by fastening bench tops
to pedestals and securely anchoring to the floor using appropriate
anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches
to operate without binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied
paint.
ACCEPTABLE MANUFACTURERS
1. Penco Products, Inc., Oaks, PA - Invincible
II Defiant II SPL Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS
CONSISTENT WITH ITS POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.