CLOSED BASES: Provide 18 gauge closed metal front and end bases on knocked down lockers having legs. Front bases shall be installed between legs without overlap or exposed fasteners. Provide end bases on exposed ends. Bases shall be finished to match lockers.
LOCKS: (Specify lock brand if desired, location and locker type if appropriate.) All locks shall have bolt types appropriate to the mode of locker operations.
Built-In Flat Key Locks: All lockers shall be equipped with built-in flat key type locks. All locks shall be master keyed to the same series. Provide two (2) keys for each lock and two (2) master keys for the system.
Built-In Grooved Key Locks (Pin Tumbler): All lockers shall be equipped with built-in grooved key type locks. All locks shall be master keyed to the same series. Provide two (2) keys for each lock and two (2) master keys for the system.
Built-in Combination Locks: All lockers shall be equipped with built-in combination locks. Locks shall have three-number combination dialing and be capable of at least five different combination changes. Master key, combination change key, if required, and combination control charts shall be provided to the owner.
Padlocks-Combination Type: Master keyed combination type padlocks shall be provided for all locker doors. Locks shall have three-number combination dialing. Master key shall be provided to the owner.
Coin Operated Locks: (Certain locker types and sizes will not accept coin locks; verify with locker manufacturer). Coin operated locks shall be provided for all lockers.
Locks shall be (select one):
Coin return/deposit type; Coin collect/pay type; Card Lock.
Coin fee shall be (select one):
Token; One (1) Quarter; Two (2) Quarters; Card Lock.
Locks are to be installed on lockers using security-type machine screws.
VISUAL
PERFORATION 16 Ga. & 18 Ga. DOORS: Locker
doors shall be provided with 5/8" x 1-1/8" visual perforations.
ROUND PERFORATION: 24
gauge Backs, Sides, Tops, Bottoms or Shelves only are to be punched
with
1/2" diameter
perforations grouped in 42 hole patterns. (For sides
and backs, specify full perforations for maximum number
of holes in the part, or standard
perforations consisting or one group top and bottom in
single-tier; one group each compartment in double-tier or box
lockers).
FIRE EXTINGUISHER DOOR: Lockers designated on drawings to contain fire extinguisher shall be double tier type with upper door to have a glazed opening. Locks are to be omitted on fire extinguisher doors.
WASTE BIN DOORS: Lockers designated on drawings to contain waste bins shall be provided with a door cut-out with a top hinged internal flap door over the cut-out. Locks are to be omitted on waste bin doors.
CENTER PARTITIONS: For Vanguard and Guardian lockers. Lockers shall have 24 gauge, full depth, vertical partitions between bottom and shelf.
RECESS TRIM: Vertical
and/or horizontal recessed trim shall be provided where shown. Trim
shall
be formed from 18 gauge sheet steel and have a 3 " face dimension. Trim shall be furnished in standard lengths as long as practical and attached to lockers with concealed clips. Finish caps and splices shall be provided as required. Trim shall be finished to match >lockers.
ZEE BASES: Knocked
down lockers shall be furnished with 4" high, 14 gauge zee base
flanged outward at top for support of lockers and inward at bottom for
anchoring
to the floor.
FRONT FILLER: Fillers for spaces between lockers or between lockers and a wall shall be fabricated from 20 gauge sheet steel and formed in an angle shape. Slip joint angles shall be 20 gauge sheet steel formed in an angle shape with a double bend on one leg to form a pocket which provides adjustable mating with the angle filler. Attachment shall be by means of concealed fasteners. Fillers shall be finished to match lockers.
EXPOSED LOCKER SIDES: Shall be furnished in 16 gauge without any extra holes.
FINISHED END PANELS: Finished
end panels shall be installed on all exposed ends of lockers. They
shall be formed from minimum 16 gauge sheet steel to match
locker depth and height,
and shall have a 1" edge dimension. All panels shall be installed
with concealed fasteners. Panels shall be finished to match
lockers.
CONTINUOUS SLOPE HOOD: Lockers
shall be provided with continuous slope hoods formed from 18 gauge
sheet steel with a slope that has a rise equal to 1/3 of
the locker depth (18-1/2
degrees), plus a 1" vertical rise at the front. Tops shall be provided
in lengths as long as practical. Provide slip joints
without visible fasteners at splice locations. Necessary
end closures shall be provided.
Tops shall be finished to match lockers.
UNIT SLOPE TOPS VANGUARD AND GUARDIAN LOCKERS: Lockers shall be provided with 24 gauge individual sloping tops. Tops shall be formed to a slope which rises 1/3 of the locker depth. Tops shall be finished to match lockers.
BENCHES: Locker
benches shall be laminated selected hardwood, 1-1/4" full finished thickness. All corners are to be rounded and sanded. Surfaces shall be finished with two coats of clear lacquer. Bench tops are to be 9-1/2" wide
and furnished in lengths of 3' through 12' (even foot increments).
HEAVY DUTY BENCH PEDESTAL: Pedestals
shall consist of steel tubing with 10 gauge steel flanges welded
to each end. The overall height of pedestal shall be 16-1/4". Pedestals
are to be finished to match the lockers.
STAINLESS STEEL FREE STANDING BENCH PEDESTAL: Shall
be 2" diameter brushed 16 gauge stainless steel formed into a trapezoid. Bottom shall be 14" wide with two 5/16" diameter holes. Pedestal shall be 16-1/4" high for an overall bench height of 17-1/2". Top flange shall have four 5/16" diameter
holes for fastening to the bench. Bench can be moveable or
may be anchored.
WIRE BASKET RACKS: Shelving:
Shelving units shall consist of 1" x 1" x 13 gauge angle posts
punched for bolting shelves. Sway braces of 12 gauge steel shall
be provided for the back and sides of the unit. Shelves
shall be 20 gauge formed
with down turned flanges at the back to act as a backstops.
Dividers: Dividers
shall be 20 gauge, 3" in height with an attaching flange formed
at right angles. Dividers are bolted to shelves.
Padlock Attachment: A padlock staple attachment shall be provided at the front edge of each shelf located to match the locking loop formed in the basket rim.
Casters (option): Mobility
casters shall be 3" diameter, swivel-type bolted to each corner
post.
Number Plates: Numbering shall consist of Penco standard aluminum number plates pop riveted to shelf face at each basket opening, and on the front of the basket.
Baskets: Baskets
shall be (select size) 12" x 13" x 8" or 9" x 13" x 8" of
(select type) all wire or wire mesh or perforated steel front type.
Pilfer Guards (option): Provide
a sheet steel pilfer guard designed for field attachment to the
top of the basket to cover the first 3 " of depth.
Finish: Finish on baskets and pilfer guards consists of electroplating with bright zinc chromate. Basket rack posts, shelves and braces to be finished in color selected from manufacturer's standard colors.
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS CONSISTENT WITH ITS POLICY OF CONTINUOUS PRODUCT IMPROVEMENT. |