This locker is the same design as the standard
Vanguard, with the exception that the die cast handle is replaced
with a deep drawn stainless steel Classic III recessed pocket.
Available as one, two or three tier, plus Two Person and Duplex
lockers.
VANGUARD WITH RECESSED POCKET LOCKER SPECIFICATIONS
MATERIALS
SHEET STEEL: All parts made from prime
grade mild cold rolled sheet steel free from surface imperfection,
and capable of taking a high grade enamel finish.
HINGES: .074" thick, 2" high,
double spun, full loop, tight pin, five-knuckle hinges, projection
welded to door frame and securely fastened to the door with 2 steel
rivets. Doors over 48" high shall have three hinges, all other doors shall have
two hinges.
FINISHING: Chemically
pretreat metal with a six stage cleaning phosphatizing and metal
preparation process. Finish
coat shall be
electrostatically applied powder coat enamel baked on at 350 to 400
degrees. Select colors from manufacturer's minimum standard 21 colors.
All
lockers
shall be painted inside and outside with the same color.
EQUIPMENT: Coat hooks and coat rods are
zinc plated. Truss fin head bolts and hex nuts are zinc coated.
FABRICATION GENERAL CONSTRUCTION: Built
on the unit principle - each locker shall have an individual door
and frame, individual top, bottom, back and shelves with common intermediate
uprights separating compartments. Lockers shall be fabricated square,
rigid and without warp. Doors shall be flat and free of distortion.
DOOR FRAME: All door frame members to be
not less than 16 gauge formed to a channel shape. Vertical members
to have an additional flange to provide a continuous door strike.
Intermembering parts to be mortised and tenoned and electrically
welded together in a rigid assembly capable of resisting strains.
Cross frame members of 16 gauge channel shapes including intermediate
cross frame on double and triple tier lockers shall be securely welded
to vertical framing members to ensure rigidity.
BODY: Bolt
spacing in locker body construction not to exceed 9" o.c. All locker body components shall be made of
cold rolled steel specially formed for added strength and rigidity
and to ensure tight joints at fastening points. Tops & bottoms shall
be 24 gauge with three sides formed 90 degrees and the front offset
formed to be flush with the horizontal frame member. Shelves shall
be 24 gauge with four sides formed to 90 degrees, the front edge
shall have a second bend. Backs & sides shall be 24 gauge.
DOORS: Doors
30" or higher shall be formed
from one piece 16 gauge cold rolled sheet steel. Doors less than
12" wide shall be 18 gauge. Formations shall consist of a full channel
shape on the lock side of adequate depth to fully conceal the lock
bar, channel formation on the hinge side, and right angle formations
across the top and bottom. Doors over 15" wide x 60" or 72" high
shall have a 3" wide 20 gauge full height reinforcing pan welded
to the inside face of the door on 6" centers.
DOOR
HANDLE & LATCHING; 1, 2 & 3 TIER, TWO
PERSON & DUPLEX: Provide handles recessed in the door with
finger lift control. 20 gauge drawn pocket shall be brushed stainless
steel securely fastened to the door with two tabs plus a positive
tamper resistant decorative fastener. The pocket shall be of sufficient
depth to prevent a combination padlock, built-in combination lock
or key lock from protruding beyond the face of the door. A lock
hole cover plate shall be provided for use with padlocks. The lifting
piece shall be 14 gauge formed steel, attached to the latching
channel with one concealed retaining lug and one rivet assuring
a positive two point connection. Handle finger lift shall have
a padlock eye for use with a 9/32" diameter padlock shackle. It
shall have a sound deadening molded comfortable finger lift attached.
Doors to have latch clip engaging the door frame at three points
on doors over 42" high and two points on all other doors. Locking
device to be positive, automatic type, whereby locker door may
be locked when open, then closed without unlocking. One rubber
silencer shall be firmly secured in the frame at each heavy gauge
latch hook. Latch clips shall be glass filled nylon for long life
and low friction and shall hold doors shut by engaging the latch
hooks. The latch channel assembly shall be quieted by the use of
unique nylon glides to reduce noise.
VENTILATION: Lockers
with doors 72" to
36" high shall have two sets of louvers, one set near the top of
the door and another set near the bottom of the door. Lockers with
doors 30" or less in height, shall have a minimum of one set of louvers.
NUMBER PLATES: Each
locker to be supplied with a polished aluminum number plate, 2-1/4" wide x 1" high, with
black numerals not less than 3/8" high. Number plates shall be attached
to the face of the door with two aluminum rivets.
INTERIOR EQUIPMENT: Single-tier
lockers 48-1/2" or higher shall have a hat shelf located approximately 9" below
the top of locker; if less than 18" deep, locker shall have three
single-prong hooks and one double-prong ceiling hook. Single tier
lockers 18" or more in depth shall have a coat rod instead of a ceiling
hook. 30" & 36" high lockers shall have three single-prong wall hooks
and one double-prong ceiling hook. Hooks to be attached with two
bolts per hook. 20" & 24" high lockers to have three wall hooks for
12" wide, and four wall hooks for 15" wide and wider.
LOCKER ACCESSORIES See locker Accessory
Specifications.
OPTIONS BODY: Locker shall be assembled
using rivets.
SIDE AND BACK VENTILATION: Sides
and/or backs shall be perforated with 1/2" diameter holes in patterns
of 42 holes per group.
DOOR VENTILATION: Visual
perforations shall consist of 5/8" wide x 1-1/8" high rectangular perforations in the
door in standard manufacturer's patterns. Doors with visual perforations
shall not have louvers. Mini louvers shall be 5/8" wide x 1/4" high
and be placed in doors in manufacturer's standard pattern. Doors
with mini louvers shall not have standard louvers.
A. D. A. COMPLIANT LOCKERS: Handicap
lockers shall have recessed handles and shall be single tier or
the lower
opening of a double tier locker. Locker bottom shall be a minimum
of 9" off the floor, or an extra shelf placed 9" off the floor. Single
tier lockers shall have a shelf 48" off the floor. Doors assigned
for handicapped use shall have an appropriate symbol sign.
EXECUTION INSTALLATION: Install metal lockers
at location shown in accordance with manufacturers instructions for
plumb, level, and flush installation.
ANCHOR LOCKERS to
the floor and wall 48" on
center or less as recommended by the manufacturer.
INSTALL SLOPING HOODS AND METAL FILLERS using
concealed fasteners. Provide flush hairline joints against adjacent
surfaces.
INSTALL BENCHES by fastening bench tops
to pedestals and securely anchoring to the floor using appropriate
anchors for the floor material.
ADJUST & CLEAN: Adjust doors and latches
to operate without binding. Verify that latches are operating satisfactorily.
TOUCH UP marred finishes with factory supplied
paint.
ACCEPTABLE MANUFACTURERS
1. Penco Products, Inc., Oaks, PA - Vanguard Recessed
Pocket Lockers
PENCO RESERVES THE RIGHT TO VARY SPECIFICATIONS
CONSISTENT WITH ITS POLICY OF CONTINUOUS PRODUCT IMPROVEMENT.
11/06
|