Quick Ship
Penco Exchange

Slope

Slope tops are often used instead of flat tops to prevent the accumulation of dust and deris, an to discourage the use of locker tops as stoage areas. There are three different types of slope top construction. Unit Slope Tops, Slope Hoods and Slope Top Kits. Each is explained below.

 UNIT SLOPE TOPS  SLOPE TOP KIT
   

 

 

 

Unit Slope tops cover the width of one locker frame only. Lockers with Unit slope Tops have sides with mitered top ends with a rise equal to 1/3 of the locker depth, plus longer backs that meet the rear edge of the slope top. Unit slope tops are used in place of the standard flat tops. Order the appropiate locker plus the proper slope top size. (Not for use on Invincible II or All Welded lockers, use Continuous Slope Top Hood listed below.)  

 

Designed to convert stock flat top lockers into slope top lockers in groups of 3 wide. Each Kit contains 3 tops, 3 backs and 4 ends. Also available for quick shipment in 028 Gray. (Not for use on Invincible II or All Welded Lockers, use Continuous Slope Top Hood listed below.)

 

 Continuous Slope Top Hood

 
 Continuous slope hoods fit on top of flat top lockers. They can be used on new lockers, or on a retrofit basis. All hoods are furnished in 72" lengths and must be cut to length during installation. Intermediate splices, ends and rear supports (2 per hood) complete the installation and must be ordered separately.

 

LOCKER FILLERS

Penco provides standard fillers to adapt lockers to a wide range of field conditions and provide a professional, finished apearance. They can be used to cover columns, pipes or other obstacles in a row of lockers or fill the gap between the lockers and a wall.

 Vertical Filler

 Top Fillers

   
 Vertical Fillers come in three widths and are designed to be used in conjunction with Wall Angle Slip Joints for a solid fit and smooth finish. The slip joint conceals any raw edges caused by field cutting.  Top Fillers cover gaps between tops of lockers. They overlap the locker tops and can be field cut to allow for pipes, etc. There are separate designs for flat top vs. slope top, and in-line vs. corner applications.

 

Zee Bases

Used to raise lockers without legs 4" off the floor when there is no concrete or wood base. They provide a toe space in the front and a concealed flange for floor anchoring at the rear. (Not for use in welded lockers.)

 Bench Tops

Exceptionally strong. Made from selected hardwood and finished with clear lacquer. Standard bench tops are 9-1/2" deep x 1-1/4" thick. Tops that are compliant with ADA (Americans With Disabilities Act) are 24" deep. Order Pedestals separately.

 

Bench Pedestals
Penco offers a choice in bench pedestal styles, as shown above. Order two pedestal for benches 96" long or less; order three pedestals for benches over 96" long. The 48" x 24" ADA bench requires 4 pedestals.                                                          

A. Heavy Duty Pedestal - 16 1/4" high.
Pedestal consists of a heavy duty steel tube welded to top and bottom flanges. Hardware for fastening to the bench only is included. Pedestal must be anchored to the floor.Order two or more pedestals per bench. Available for quick shipment in 028 Gray and 073 Champagne. Available on production orders in all 21 colors.

B. Stainless Steel Free Standing Pedestal - 16-1/4" high.
This pedestal has a 14" wide base which allows for movable free standing use. Holes in the bottom are provided for optional floor anchoring. Hardware supplied for fastening to the bench top.


Locks

Penco lockers are designed to accept built-in key or combination locks, padlocks and in certain circumstances coin or card locks. Locks are always ordered separately.

Built-In Key Locks

Flat key or grooved key models available. Can be obtained in different key combinations or key combinations or keyed alike. Reversible for LH & RH applications.


Built-in Combination Locks

Five combination changes for security. Master Key controlled. Available in LH & RH models.

Combination Padlock

Available with and without masterkeying. 3 number dialing. Rust resistant. fits all Penco lcokers.

Coin/Card Operationed

Ideal for public or private applications that require security with the assurance that keys will be returned or as a revenue producer. Coin and token locks fit most Penco lockers. Available in 4 types; coin return, coin collection or token operation. Not available for Defiant lockers. Card activated locks fit some lockers with special modifications.

 

 

 

Penco Steel  Locker Accessory Specifications

 

CLOSED BASES:  Provide 18 gauge closed metal front and end bases on knocked down lockers having legs.  Front bases shall be installed between legs without overlap or exposed fasteners.  Provide end bases on exposed ends.  Bases shall be finished to match lockers.

LOCKS:  (Specify lock brand if desired, location and locker type if appropriate.)  All locks shall have bolt types appropriate to the mode of locker operations.

Built-In Flat Key Locks:  Lockers shall be equipped with built-in flat key type locks.  All locks shall be master keyed to the same series.  Provide two (2) keys for each lock and two (2) master keys for the system.

Built-In Grooved Key Locks (Pin Tumbler):  Lockers shall be equipped with built-in grooved key type locks.  All locks shall be master keyed to the same series.  Provide two (2) keys for each lock and two (2) master keys for the system.

Built-in Combination Locks:  Lockers shall be equipped with built-in combination locks.  Locks shall have three-number combination dialing and be capable of at least five different combination changes.  Master key, combination change key, if required, and combination control charts shall be provided to the owner.

 

Padlocks-Combination Type:  Master keyed combination type padlocks shall be provided for all locker doors.  Locks shall have three-number combination dialing.  Master key shall be provided to the owner.

 

Coin Operated Locks:  (Certain locker types and sizes will not accept coin locks; verify with locker manufacturer).

Coin operated locks shall be provided for lockers.

Locks shall be (select one):

Coin return/deposit type; Coin collect/pay type; Card Lock.

Coin fee shall be (select one):

Token; One (1) Quarter; Two (2) Quarters; Card Lock.

Locks are to be installed on lockers using security-type machine screws.

 

VISUAL PERFORATION 16 Ga. & 18 Ga.:  Locker doors shall be provided with 5/8" x 1-1/8" rectangular visual perforations.

 

ROUND PERFORATION:  24 gauge (Backs, Sides, Tops, Bottoms or Shelves) are to be punched with 1/2" diameter perforations grouped in 42 hole patterns.  (For sides and backs, specify full perforations for maximum number of holes in the part, or standard perforations consisting or one group top and bottom in single-tier; one group each compartment in double-tier or box lockers).

 

FIRE EXTINGUISHER DOOR:  Lockers designated on drawings to contain fire extinguisher shall be double tier type with upper door to have a glazed opening.  Locks are to be omitted on fire extinguisher doors.

 

WASTE BIN DOORS:  Lockers designated on drawings to contain waste bins shall be provided with a door cut-out with a top hinged internal flap door over the cut-out.  Locks are to be omitted on waste bin doors.

CENTER PARTITIONS:  Lockers shall have 24 gauge, full depth, vertical partitions between bottom and shelf.

 

RECESS TRIM:  Vertical and/or horizontal recessed trim shall be provided where shown.  Trim shall be formed from 18 gauge sheet steel and have a 3" face dimension.  Trim shall be furnished in standard lengths as long as practical and attached to lockers with concealed clips.  Finish caps and splices shall be provided as required.  Trim shall be finished to match lockers.

 

ZEE BASES:  Knocked down lockers shall be furnished with 4" high or 6" high 14 gauge zee base flanged outward at top for support of lockers and inward at bottom for anchoring to the floor. Not for use for Stadium and Welded Lockers.

 

FRONT FILLER:  Fillers for spaces between lockers or between lockers and a wall shall be fabricated from 20 gauge sheet steel and formed in an angle shape.  Slip joint angles shall be 20 gauge sheet steel formed in an angle shape with a slot on one leg to form a pocket which provides adjustable mating with the angle filler.  Attachment shall be by means of concealed fasteners.  Fillers shall be finished to match lockers.

 

EXPOSED LOCKER SIDES:  Shall be furnished in 16 gauge without any extra holes.

 

FINISHED END PANELS:   Finished end panels shall be installed on all exposed ends of lockers.  They shall be formed from minimum 16 gauge sheet steel to match locker depth and height, and shall have a 1" edge dimension.  All panels shall be installed with concealed fasteners.  Panels shall be finished to match lockers.

 

CONTINUOUS SLOPE HOOD:   Lockers shall be provided with continuous slope hoods formed from 18 gauge sheet steel with a slope that has a rise equal to 1/3 of the locker depth (18-1/2o ), plus a 1" vertical rise at the front.  Tops shall be provided in lengths as long as practical.  Provide slip joints without visible fasteners at splice locations.  Necessary end closures shall be provided.  Tops shall be finished to match lockers.

 

UNIT SLOPE TOPS VANGUARD AND GUARDIAN LOCKERS:   Lockers shall be provided with 24 gauge individual sloping tops.  Tops shall be formed to a slope which rises 1/3 of the locker depth.  Tops shall be finished to match lockers.

 

BENCHES:  Locker benches shall be laminated selected hardwood, 1-1/4" full finished thickness.  All corners are to be rounded and sanded.  Surfaces shall be finished with two coats of clear lacquer.  Bench tops are to be 9-1/2" wide and furnished in lengths of 3' through 12' (even foot increments).

 

HEAVY DUTY BENCH PEDESTAL:  Pedestals shall consist of steel tubing with 10 gauge steel flanges welded to each end.  The overall height of pedestal shall be 16-1/4".  Pedestals are to be finished to match the lockers.

 

STAINLESS STEEL FREE STANDING BENCH PEDESTAL:  Shall be 2" diameter brushed 16 ga. stainless steel formed into a trapezoid.  Bottom shall be 14" wide with two 5/16" diameter holes.  Pedestal shall be 16-1/4" high for an overall bench height of 17-1/2".  Top flange shall have four 5/16" diameter holes for fastening to the bench.  Bench can be moveable or may be anchored.

 

WIRE BASKET RACKS:  Shelving:  Shelving units shall consist of 1" x 1" x 13 gauge angle posts punched for bolting shelves.  Sway braces of 12 gauge steel shall be provided for the back and sides of the unit.  Shelves shall be 20 gauge formed with downturned flanges at the back to act as a backstops.

 

Dividers:  Dividers shall be 20 gauge, 3" in height with an attaching flange formed at right angles.  Dividers are bolted to shelves.

Padlock Attachment:  A padlock staple attachment shall be provided at the front edge of each shelf located to match the locking loop formed in the basket rim.

Casters (option):  Mobility casters shall be 3" diameter, swivel-type bolted to each corner post.

Number Plates:  Numbering shall consist of Penco standard aluminum number plates pop riveted to shelf face at each basket opening, and on the front of the basket.

Baskets:  Baskets shall be (select size) 12" x 13" x 8" or 9" x 13" x 8" of (select type) all wire or wire mesh or perforated steel front type.

Pilfer Guards (option):  Provide a sheet steel pilfer guard designed for field attachment to the top of the basket to cover the first 3" of depth.

Finish:  Finish on baskets and pilfer guards consists of electroplating with bright zinc chromate.  Basket rack posts, shelves and braces to be finished in color selected from manufacturer’s standard colors.

 

Penco Products, Inc. reserves the right to vary

specifications consistent with a policy of continuous

product improvement.

 

 

 

 

 LOCKER FINISHES
In addition to our standard finish, Penco lockers are available with PowderCoatplus or X-Off Anti-Graffiti Paint.

STANDARD FINISH
Penco's standard powder coat finish is perfect for most locker applications. The paint surface has been proven to be tough and durable.


An optional extra thick 2 mil coating of powder coat paint which provides added protection from scratches and rust.


A finish that offers superior long term protection from unsightly graffiti.