Stadium® Sports Lockers

Penco’s Stadium® lockers are ideally suited for sports team rooms, fire fighter’s equipment, or any other environment where easy access to uniforms and/or equipment is required.

Stadium lockers are available in Knocked Down or Welded construction. The open front and diamond perforated sides create full ventilation while allocating a specific storage space to each individual. The base model has a full-width shelf, 2 coat hooks, and a coat rod. A lockable security box, lockable foot locker that doubles as a bench, or both can be added to the Stadium locker.

When fully accessorized, Stadium lockers are outfitted with a security box fastened to a full-width shelf and a footlocker with a hinged, reinforced seat at the base. Both compartments are lockable to secure valuable items. The front of the footlocker is recessed for an external padlock, and a stainless steel strike plate protects the finish. The footlocker design saves floor space by eliminating the clutter of open locker doors and the need for separate locker room benches.

 

  • 1135
  • 1132
  • Stadium® Lockers
  • Stadium® Lockers
  • Stadium® Lockers
  • Stadium® Lockers
  • Stadium® Lockers
  • Stadium® Lockers
  • Stadium® Lockers

Penco Stadium® lockers have an open front and perforated sides providing a fully ventilated space for storage of athletic gear or other items. The base model is an open shell with a full width shelf. A security box fastened to the shelf and a foot locker with a hinged, reinforced seat at the base are popular options. They are available in 24" or 33" widths and 18", 21" or 24" depths. An 18" wide locker is also available with an 18" depth only. K.D. Stadium lockers are 72" high. Welded Stadium lockers are 76" high, which includes a 4" high integral base.

SECTION 10 51 13
METAL LOCKERS

PART 1 – GENERAL

1.01 SECTION INCLUDES

  • 1.01.A Open Front Welded Team Lockers.
  • 1.01.B Locker benches.

1.02 SUBMITTALS

  • 1.02.A Submit under provisions of Section 01 33 00.
  • 1.02.B Manufacturer's data sheets on each product to be used, including:
  • 1.02.B.1 Preparation instructions and recommendations.
  • 1.02.B.2 Storage and handling requirements and recommendations.
  • 1.02.B.3 Installation methods.
  • 1.02.C Shop Drawings: Show the following:
  • 1.02.C.1 Dimensioned drawings including plans, elevations, and sections to show locker locations and interfaces with adjacent substrates.
  • 1.02.C.2 Details of assembly, erection, anchorage and clearance requirements.
  • 1.02.D Selection Samples:  For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and finishes.

1.03 DELIVERY, STORAGE, AND HANDLING

  • 1.03.A Store products in manufacturer's unopened packaging until ready for installation.
  • 1.03.B Protect locker finish and adjacent surfaces from damage.

PART 2 - PRODUCTS  

2.01 MANUFACTURERS

  • 2.01.A Acceptable Manufacturer: Penco Products, Inc., which is located at: 2024 Cressman Rd. P. O. Box 158 ; Skippack, PA 19474-0158; Toll Free Tel: 800-562-1000; Tel: 610-666-0500; Fax: 610-666-7561; Email:general@pencoproducts.com; Web: www.pencoproducts.com
  • 2.01.B Substitutions:  Not permitted.
  • 2.01.C Requests for substitutions will be considered in accordance with provisions of Section 01 25 00.
  • 2.01.D Provide only metal lockers fabricated in the United States by a single domestic manufacturer.

2.02 MATERIALS

  • 2.02.A Steel:  Prime grade mild cold-rolled sheet steel free from surface imperfection, capable of taking a high-grade enamel finish and in compliance with ASTM A1008.
  • 2.02.B Steel:  Sheet steel components shall be fabricated using zinc-coated steel free from surface imperfection, capable of taking a high-grade enamel finish and in compliance with ASTM A879.
  • 2.01.C Hooks:  Zinc plated forged steel, ball ends.
  • 2.01.D Bolts and Nuts:  Zinc plated truss fin head bolts and hex nuts.

2.03 HEAVY DUTY LOCKERS

  • 2.03.A Heavy Duty Lockers: All locker body components made of cold rolled steel speciallyformed for added strength and rigidity and to ensure tight joints at fastening points.
  • 2.03.A.1 Open-Front Athletic Lockers:  Penco Stadium lockers, welded, with 4 inch (101 mm) high integral base (standard).
  • 2.03.B Locker Body: Stadium Open Front Welded Lockers.
  • 2.03.B.1 Sides, Bottoms, Tops, and Shelves:
  • 2.03.B.1.a 16 gauge steel.
  • 2.03.B.2 Backs:  Solid 18 gauge steel.
  • 2.03.B.3 Framing: All locker body components made of cold rolled steel specially formed for added strength and rigidity and to ensure tight joints at fastening points.
  • 2.03.B.4 Parts mortised and tenoned and welded in a rigid assembly.
  • 2.03.B.5 Shelves:  Flanged four sides with additional return flange on front edge to increase strength.
  • 2.03.B.6 Integral Metal Base:  4-inch (101 mm) high 16 gauge steel channel, welded to the locker bottom.

2.04 INTERIOR EQUIPMENT

  • 2.04.A Stadium Open-Front Athletic Lockers:
  • 2.04.A.1 Full width shelf, coat rod, and two single prong hooks.
  • 2.04.A.2 Box locker security box, above shelf.
  • 2.04.A.2.a Door shall be 14 gauge steel, punched for built-in lock or padlock. Lock hole cover with door pull shall be provided for padlock use.
  • 2.04.A.2.b Hinges: 16 gauge continuous and riveted to 16 gauge welded frame
  • 2.04.A.2.c Side panel: 16 gauge
  • 2.04.A.3 Foot locker with hinged bench seat, padlock hasp and stainless steel strike.
  • 2.04.A.3.a Hinge: 16 gauge continuous and riveted to horizontal panel
  • 2.04.A.3.b Ventilation: Front panel to have a pattern of mini louvers that measure ½ inch (12.7 mm) wide by ¼ inch (6.35 mm) high.

2.05 ACCESSORIES

  • 2.05.A Number Plates:  Provide each locker with a polished aluminum number plate, 2-1/4 inches (57 mm) wide by 1 inch (25 mm) high, with black numerals not less than 3/8 inch (9.5 mm) high; attach to face of door with two aluminum rivets.
  • 2.05.B Locks:  Built-in flat key locks; control-key to same series.
  • 2.05.C Locks:  Built-in grooved key locks (pin tumbler); control-key to same series.
  • 2.05.D Continuous Sloped Hoods:  18 gauge steel, slope rise equal to 1/3 of the locker depth (18.5 degrees), plus a 1 inch (25 mm) vertical rise at front.
  • 2.05.D.1 Supplied in 72 inch (1829 mm) lengths only.
  • 2.05.D.2 Slip joints without visible fasteners at splice locations.
  • 2.05.D.3 Provide necessary end closures.
  • 2.05.D.4 Finish to match lockers.
  • 2.05.E Continuous Sloped Hoods:  16 gauge steel, slope rise equal to 1/3 of the locker depth (18.5 degrees), plus a 1 inch (25 mm) vertical rise at front.
  • 2.05.E.1 Supplied in 72 inch (1829 mm) lengths only.
  • 2.05.E.2 Slip joints without visible fasteners at splice locations.
  • 2.05.E.3 Provide necessary end closures.
  • 2.05.E.4 Finish to match lockers.
  • 2.05.F Finished End Panels:  Minimum 16 gauge steel formed to match locker depth and height, 1 inch (25 mm) edge dimension; finish to match lockers and install with concealed fasteners.
  • 2.05.G Front Fillers:  20 gauge steel formed in an angle shape, with 20 gauge slip joint angles formed in an angle shape with double bend on one leg forming a pocket to provide adjustable mating with angle filler.
  • 2.05.G.1       Attachment by means of concealed fasteners.
  • 2.05.G.2 Finish to match lockers.
  • 2.05.H Recess Trim:  18 gauge steel, 3 inch (75 mm) face dimension.
  • 2.05.H.1 Vertical and/or horizontal as required.
  • 2.05.H.2 Standard lengths as long as practical.
  • 2.05.H.3 Attach to lockers with concealed clips.
  • 2.05.H.4 Provide necessary finish caps and splices.
  • 2.05.H.5 Finish to match lockers.
  • 2.05.I Benches:  Laminated selected hardwood, 1-1/4 inch (31 mm) full finished thickness, corners rounded and sanded, surfaces finished with two coats of clear lacquer.
  • 2.05.I.1 Width: 9-1/2 inches (240 mm) wide.
  • 2.05.I.2 Width: 12 inches (305 mm) wide.
  • 2.05.I.3 Width: 24 inches (610 mm) wide.
  • 2.05.I.4 Lengths:  As shown.
  • 2.05.J Heavy-Duty Bench Pedestals:  Steel tubing with 10 gauge steel flanges welded to each end, 16-1/4 inches (412 mm) high, finish to match lockers.
  • 2.05.K Stainless Steel Free-Standing Bench Pedestals:  2-inch (50 mm) diameter brushed 16 gauge stainless steel formed into a trapezoid, 14 inch (355 mm) wide bottom with two 5/16 inch (7.9 mm) diameter holes, top flange with four 5/16 inch (7.9 mm) diameter holes for fastening to bench.

2.06 FABRICATION

  • 2.06.A Fabricate lockers square, rigid, without warp, with metal faces flat and free of distortion.
  • 2.06.B Welded Lockers:  Pre-assemble lockers by welding into one piece structures in groupings most practical for job requirements, welds free of burrs; maximum width of group to be 54 inches (1.371 m); no bolts, nuts, or rivets allowed in assembly of main locker groups.
  • 2.06.C Finish:  Enamel powder coat paint finish electrostatically applied and properly cured to manufacturer’s specifications for optimum performance. Finishes containing volatile organic compounds and subject to out-gassing are not acceptable. Locker exterior and interior shall be painted the same color.
  • 2.06.C.1 Powder Coat - Dry Thickness:  1 to 1.2 mils (0.025 to 0.03 mm).
  • 2.06.C.2 Powder Coat Plus - Dry Thickness:  2 to 2.2 mils (0.05 to 0.055 mm).
  • 2.06.C.3 Color:  As selected from manufacturer's standard colors.
  • 2.06.C.4 Special Finish
  • 2.06.C.4.a Custom color
  • 2.06.C.4.b Anti-Graffiti
  • 2.06.C.4.c.Anti-Microbial
  • 2.06.C.4.d TGIC
  • 2.06.C.4.e Ultra-Weatherable. 

PART 3 – EXECUTION

3.01 EXAMINATION

  • 3.01.A Do not begin installation until substrates and bases have been properly prepared.
  • 3.01.B If substrate and bases are the responsibility of another installer, notify Architect ofunsatisfactory preparation before proceeding.

3.02 INSTALLATION

  • 3.02.A Install metal lockers and accessories at locations shown in accordance with manufacturer's instructions.
  • 3.02.B Install lockers plumb, level, and square.
  • 3.02.C Anchor lockers to floor and wall at 48 inches (1.219 m) or less, as recommended by the manufacturer.
  • 3.02.D Bolt adjoining locker units together to provide rigid installation.
  • 3.02.E Install sloping tops and metal fillers using concealed fasteners.  Provide flush hairline joints against adjacent surfaces.
  • 3.02.F Install benches by fastening bench tops to pedestals and securely anchoring to the floor using appropriate anchors for the floor material.

3.03 ADJUSTING AND CLEANING

  • 3.03.A Adjust doors and latches to operate without binding. Verify that latches are operating satisfactorily.
  • 3.03.B Adjust built-in locks to prevent binding of dial or key and ensure smooth operation prior to substantial completion.
  • 3.03.C Touch-up with factory-supplied paint and repair or replace damaged products before substantial completion.

3.04      PROTECTION

  • 3.04.A Protect installed products until completion of project.

END OF SECTION

10 51 13

Penco Products, Inc. reserves the right to vary specifications consistent with a policy of continuous product improvement.

Color Number Color Name Color
054 Canvas  
021 Gray Ash  
028 Gray  
073 Champagne  
723 Light Putty  
012 Tawny Tan  
701 Spray Green  
952 Turquoise Teal  
055 Shamrock  
812 Hunter Green  
715 Lake Blue  
826 Slate Blue  
806 Marine Blue  
052 Reflex Blue  
822 Regal Blue  
058 Nordic Purple  
056 Sunburst  
710 Sagebrush Yellow  
720 Mandarin Orange  
722 Patriot Red  
767 Cardinal Red  
736 Burgundy  
848 January White  
949 Jet Black  

NOTE: Colors shown are as close to actual finishes as the printing process allows. Do not make your final color selection based on the color shade shown on this page. Penco Color Charts are available for a more accurate color match. Exposure to high humidity, chlorine salts, abrasive cleaners, germicidal cleaners and acids can damage the finish and will void the guarantee. For outdoor applications or other harsh environmental conditions, contact your Penco Representative.

Configurator

View Our Configurator

Our configurator allows you to find a Penco product to meet your specific needs.

Start Now
Our Location
Our Location

Penco Products, Inc.
1820 Stonehenge Drive,
Greenville NC 27858

Contact Us
Contact Us

Phone: 800-562-1000
Fax: 800-248-1555

Log In
Log In

Please log into Penco
to gain access to images,
price lists & more